# Required parameters for termination X ('a' or 'b'):
#
# ```
# termination_x_name -> name of interface
# termination_x_device -> name of the device interface belongs to
# termination_x_class -> required if different than 'Interface' which is the default
# ```
#
# Supported termination classes: Interface, ConsolePort, ConsoleServerPort, FrontPort, RearPort, PowerPort, PowerOutlet
#
#
# If a termination is a circuit then the required parameter is termination_x_circuit.
# Required parameters for a circuit termination:
#
# ```
# termination_x_circuit:
# term_side -> termination side of a circuit. Must be A or B
# cid -> circuit ID value
# site OR provider_network -> name of Site or ProviderNetwork respectively. If both provided, Site takes precedence
# ```
#
# If a termination is a power feed then the required parameter is termination_x_feed.
#
# ```
# termination_x_feed:
# name -> name of the PowerFeed object
# power_panel:
# name -> name of the PowerPanel the PowerFeed is attached to
# site -> name of the Site in which the PowerPanel is present
# ```
#
# Any other Cable parameters supported by Netbox are supported as the top level keys, e.g. 'type', 'status', etc.
#
# - termination_a_name: console
# termination_a_device: spine
# termination_a_class: ConsolePort
# termination_b_name: tty9
# termination_b_device: console-server
# termination_b_class: ConsoleServerPort
# type: cat6
#
- termination_a_name: to-server02
termination_a_device: server01
termination_b_name: to-server01
termination_b_device: server02
status: planned
type: mmf
- termination_a_name: eth0
termination_a_device: server02
termination_b_circuit:
term_side: A
cid: Circuit_ID-1
site: AMS 1
type: cat6
- termination_a_name: psu0
termination_a_device: server04
termination_a_class: PowerPort
termination_b_feed:
name: power feed 1
power_panel:
name: power panel AMS 1
site: AMS 1
- termination_a_name: outlet1
termination_a_device: server04
termination_a_class: PowerOutlet
termination_b_name: psu1
termination_b_device: server04
termination_b_class: PowerPort